bibo:abstract
  • Among many kinds of methodologies for measuring VOCs, the passive sampling has been known as one of the most effective and accurate method. In this study, in order to evaluate the appropriate sampling time criteria for the passive sampling, the precision for the replicate samples and instrument detection limit for benzene and toluene with a liquid injection/GC/FID have been examined by OSHA's procedure. The relative standard deviation(RSD.%) of the retention time for the benzene and tolune were 0.58% and 0.38%, respectively. In case of the peak area, RSD for benzene and toluene were 6.99% and 6.66%. Consequently, the instrument detection limits for the passive sampling were 91.85pg for benzene and 43.60pg for toluene. Considering the sampling rate and recovery coefficient of thepassive sampler(OVM 3500, 3M), it was found that the minimum sampling time of benzene and toluene in the urban area should be three days. Therefore, the sampling time would be recommended over 7 days(170 hours) according to the ambient concentration level, and in this case the detection limit for the passive sampling of benzene and toluene was estimated to be 0.83ppb and 0.36 ppb, respectively. (rdf:langString) (en)
  • 대기 중 VOCs를 평가하는 여러 방법 중 passive sampling 원리를 이용하여 목적성분을 채취하고 분석하는 방법은 효율적이며 정확한 측정방법의 하나로 알려져 왔다. 본 연구에서는 passive sampling 에 의해 대기 중 목적성분을 채취할 경우 요구되는 시료채취시간에 대해 살펴보기 위하여 액상주입/GC/FID system의 벤젠과 톨루엔에 대한 검출재현성 및 OSHA 규정에 의한 기기검출한계를 평가하였다. 상대표준편차(RSD,%)를 이용하여 체류시간 및 피크면적에 대한 재현성을 평가한 결과 체류시간의 경우 벤젠 0.58%, 톨루엔0.38%,피크면적의 경우 벤젠6.99%.톨루엔6.66%로 나타나 검출재현성은 매우 우수한 것으로 나타났으며, OSHA규정 의해 평가결과와 passive sampling(OVM3500, 3M)의 시료채취속도 및 회수계수를 고려하여 기존에 보고된 도심지에서 검출되는 목적성분을 동시에 평가하고자 할 경우 필요한 시료채취 시간을 추정한 결과 약3일간 시료채취가 이루어져야 하는 것으로 나타났으며, 농도범위가 다양한 일반 대기환경 중의 목적성분의 검출을 위해 시료채취시간을 달리하며 평가한 결과 약 7일(170시간)의 시료채취시간이 적절하며, 동일조건에서의 검출한계 농도는 벤젠 0.83ppb.톨루엔0.37ppb수준인 것으로 나타났다. (rdf:langString) (ko)
nlon:biographicalNote
  • 김선태, 대전대학교 제1공학부 환경공학전공 (xsd:string)
  • 김학민, 대전대학교 제1공학부 환경공학전공, envsys (rdf:langString) (dragon.taejon.ac.kr)
nlon:classificationNumberOfNLK
  • 539.905 (xsd:string)
nlon:containedIn
dc:creator
  • 김선태 (xsd:string)
  • 김학민 (xsd:string)
dcterms:creator
nlon:datePublished
  • 2021-01-30T23:37:12 (xsd:dateTime)
dcterms:description
  • Evaluation of detection limit and sampling time of passive sampler for the GC/FID analysis of VOC (xsd:string)
bibframe:extent
  • 29 cm (xsd:string)
  • p. 839-848 (xsd:string)
  • 삽도 (xsd:string)
dcterms:isPartOf
nlon:issuedYear
  • 2001 (xsd:string)
nlon:itemNumberOfNLK
  • 대495ㄷ (xsd:string)
rdfs:label
  • Passive sampling-GC/FID에 의한 VOC 분석시 기기검출한계 평가와 시료채취시간 산정에 관한 연구 / 김학민, 김선태 (xsd:string)
dcterms:language
dc:subject
  • Analysis (xsd:string)
  • Detection (xsd:string)
  • Evaluation (xsd:string)
  • FID (xsd:string)
  • GC (xsd:string)
  • Instrument (xsd:string)
  • Limit (xsd:string)
  • Passive sampling (xsd:string)
  • Sampler (xsd:string)
  • Sampling rate (xsd:string)
  • Time (xsd:string)
  • VOCs (xsd:string)
  • 기기검출한계 (xsd:string)
  • 분석시 (xsd:string)
  • 산정 (xsd:string)
  • 시료채취속도 (xsd:string)
  • 시료채취시간 (xsd:string)
  • 평가 (xsd:string)
  • 휘발성 유기화합물 (xsd:string)
dcterms:title
  • Passive sampling-GC/FID에 의한 VOC 분석시 기기검출한계 평가와 시료채취시간 산정에 관한 연구 (xsd:string)
rdf:type
nlon:volumeOfNLK
  • 23(5) (xsd:string)